by ByOwnerHub

Home Inspection Checklist

Know what your inspector is checking โ€” and what to ask about when they find issues.

๐Ÿ 

Exterior & Foundation

  • โ˜Foundation cracks (horizontal = serious, vertical/diagonal = monitor)
  • โ˜Grading slopes away from foundation (1 inch per foot for 6 feet)
  • โ˜Gutters and downspouts: attached, clear, extend 4+ feet from foundation
  • โ˜Driveway and walkway condition
  • โ˜Deck/porch: ledger board, posts, footings, railings
  • โ˜Garage: door auto-reverse, GFCI outlets, fire separation from living space
  • โ˜Siding condition: rot, gaps, missing sections
  • โ˜Window and door caulking
๐Ÿ”บ

Roof

  • โ˜Estimated remaining life of roofing material
  • โ˜Missing, curling, or cracked shingles
  • โ˜Flashing at chimneys, valleys, skylights, and penetrations
  • โ˜Gutters: rust, holes, proper slope, secure attachment
  • โ˜Chimney: crown, cap, mortar joints, liner
  • โ˜Attic: ventilation ratio, insulation R-value, signs of water intrusion or ice dams
โšก

Electrical

  • โ˜Panel: capacity (100A minimum, 200A recommended), no double-tapped breakers
  • โ˜GFCI protection: all bathrooms, kitchen counters, garage, exterior, basement
  • โ˜AFCI protection: bedrooms (required in newer homes)
  • โ˜Smoke detectors: within 15 feet of bedrooms, on each floor
  • โ˜Carbon monoxide detectors: near sleeping areas, per local code
  • โ˜No knob-and-tube or aluminum wiring (safety hazards)
  • โ˜All outlets grounded and functional
๐Ÿšฟ

Plumbing

  • โ˜Water pressure: 40โ€“80 PSI (test at exterior hose bib)
  • โ˜Water heater: age (10โ€“12 yr lifespan), TPR valve, expansion tank if needed
  • โ˜No lead or galvanized supply pipes (replacement priority)
  • โ˜Drain slope: 1/4 inch per foot minimum
  • โ˜Visible leaks under sinks, around toilets, at water heater
  • โ˜Shut-off valves: operational at each fixture and main
  • โ˜Sewer clean-out access present
๐ŸŒก๏ธ

HVAC

  • โ˜Furnace/heat pump age and condition (15โ€“20 yr lifespan)
  • โ˜AC age and condition (10โ€“15 yr lifespan)
  • โ˜Filter condition
  • โ˜Ductwork: insulated in unconditioned space, no visible leaks or damage
  • โ˜Registers: adequate supply and return airflow in each room
  • โ˜Combustion air supply for gas appliances
  • โ˜Exhaust fans: bathroom and kitchen vented to exterior (not just attic)
๐Ÿ›‹๏ธ

Interior

  • โ˜Ceilings: water stains, cracks, signs of active leaks
  • โ˜Walls: cracks, moisture, efflorescence in basement
  • โ˜Floors: soft spots (rot/subfloor damage), uneven areas
  • โ˜Staircase: handrails secure, spindles 4 inches or less apart
  • โ˜Windows: operate, latch, fog between panes (failed seal)
  • โ˜Doors: operate and latch properly, weatherstripping
  • โ˜Bathroom: tub/shower caulking, tile grout, toilet secure to floor